Connect the new MS430502M chassis to the last one installed using an Ethernet
cable (straight or crossover)
It is necessary to enable the second or slave Ethernet port on the last
MS430502M chassis in order to allow communication with the next MS430502M
chassis.
Enable Ethernet port
Set to “off” the object: mgnt2CtrlEthPort2Disable
Location:...\microsens\mgnt2\mgnt2Hardware\mgnt2controls\ mgnt2CtrlethPort2\
Configuration
Using the procedure outlined in the MS430502M chassis User manuals: set the IP
address of the new MS430502M chassis and Manager.
End procedure
Using the Data Communication Channel
In order to manage a distant MS430502M chassis, it is possible to use the Data
Communication Channel interface. This is a 10Mb/s interface available on almost all
MICROSENS MS series modules.
Check av ailability of DCC on MS modules technical specifications
Figure 16: Connecting two MS430502M chassis with DCC