19'' 6U Chassis page 10/71
Figure 9: MS430502M chassis Front view.
Installing the MS430502M chassis
Rack mount Installation
Securely attach one rackmounting bracket on each side of the front of the chassis with
the provided screws. Align the mounting holes in the brackets with the holes in the
rack and secure using the remaining screws in the supplied kit.
Powering up
There are two power inlets to enable backup in case of failure. The second connection
is optional. Before applying the power verify that the chassis is securely positioned and
that the equipment and cables are not damaged in any way. There is no on/off switch
on the MS430502M chassis. Turning on and off the unit is achieved by connecting and
disconnecting the power lead(s).
Procedure
Using an On-Site -48V Supply:
• Check that all the components are correctly seated and secured
• Connect the MS430502M chassis to the ground using the Ground screw on
one of the two rack mounting brackets (see following picture)