19'' 6U Chassis page 12/71
Preventive Maintenance
Dust Filter replacement Procedure
The dust filter should be visually examined on a six month basis.
Procedure
• Using a cross head screwdriver loosen the two holding screws on the
frontplate, located at both sides of the FAN front panel (see picture below)
• Replace the dust filter on the FAN front panel
• Put back the FAN front panel
• Using a cross head screwdriver tighten the two holding screws on the
frontplate, located at both sides of the FAN front panel
• Check that the dust filter presence LED is green on the FAN front panel
End procedure
Figure 11: FAN front panel.
Corrective Maintenance
Management Board MGNT
MGNT Replacement Procedure
Use the following procedure to replace a MGNT management board:
Procedure
• Perform a full inventory on the MGNT using the objects:
mgnt2RinvHwPlatform
mgnt2RinvSoftwarePackage
mgnt2RinvGateware
mgnt2RinvAgent
Location: ...\microsens\mgnt2\mgnt2RemoteInventory