19'' 6U Chassis page 54/71
Location:...\microsens\mgnt2\mgnt2ConfigManagement\mgnt2CnfUploadConfigF
ilesTable
Open a Command Line Interface window from your operating system and go
to the directory where you placed the new package.
Enter the line (Windows XP):
T:\home\> tftp -i 192.168.16.123 PUT config /tftpboot/config
Where:
T:\home – is the location of the package on your PC
config - is the name of the configuration file you wish to download and
destfile.txt – is the name of the destination file on you PC
192.168.16.123 - is the IP address of the MS430502M chassis into which the
package is to be loaded.
Return of the prompt indicates completion of download.
Check that your configuration file is loaded correctly by consulting the table:
mgnt2CnfUploadConfigFilesTable
Location: …\microsens\mgnt2\mgnt2ConfigManagement
And verify that your file is located in this table, check the file name of your
file with the value of:
mgnt2CnfConfigFileName
Your configuration file is now in the RAM memory and ready for transferring to the
FLASH memory of the MGNT management board.
2. Transferring
The object of this phase is to transfer the configuration file previously loaded into the
RAM to the FLASH
Use your SNMP browser to check the backup file presence in the FLASH
memory of the MGNT board using the table:
mgnt2CnfManageConfigFilesTable
Location: …\microsens\mgnt2\mgnt2ConfigManagement
If there is already a backup file dedicated to your target MSxxxxxxx module, the
file will be overwritten with the new backup configuration file.
Since each backup file present in the FLASH memory is dedicated to a slot
number, it is necessary to specify the target slot number of the configuration file
before transferring it from the RAM memory to the FLASH memory.
Specify the target slot number using the object:
mgnt2CnfConfigSlot associated with the required configuration file
Location:...\microsens\mgnt2\mgnt2ConfigManagement\mgnt2CnfUploadConfigF
ilesTable
Set to “on” the object:
mgnt2CnfConfigUpload associated with the required configuration
file