OID Name Access Description
1.3.6.1.4.1.20044.21.3.2.18 ms430580mMesrline1TxBias r Line 1 SFP Laser bias: This OID gives
the bias value of the transceiver Line
1, read from the
DDM (Digital Diagnostic Monitoring)
(Unit = mA)
1.3.6.1.4.1.20044.21.3.2.19 ms430580mMesrline1TxPower r Line 1 SFP Transmitted Power: This
OID gives the transmit power value of
the transceiver Line 1, read from the
DDM (Digital Diagnostic Monitoring)
(Unit = dBm)
1.3.6.1.4.1.20044.21.3.2.20 ms430580mMesrline1RxPower r Line 1 SFP Received Power: This OID
gives the receive power value of the
transceiver Line 1, read from the DDM
(Digital Diagnostic Monitoring) (Unit
= dBm)
1.3.6.1.4.1.20044.21.3.3 ms430580mMesrLine
1.3.6.1.4.1.20044.21.3.3.24 ms430580mMesrline2Temperature r Line 2 SFP Temperature :This OID
gives the temperature of the
transceiver Line 2, read from the DDM
(Digital Diagnostic Monitoring) (Unit
= °C)
1.3.6.1.4.1.20044.21.3.3.25 ms430580mMesrline2Volt r Line 2 SFP Power Supply: This OID
gives the voltage of the transceiver
Line 2, read from the DDM (Digital
Diagnostic Monitoring) (Unit = V)
1.3.6.1.4.1.20044.21.3.3.26 ms430580mMesrline2TxBias r Line 2 SFP Laser bias: This OID gives
the bias value of the transceiver Line
2, read from the DDM (Digital
Diagnostic Monitoring) (Unit = mA)
1.3.6.1.4.1.20044.21.3.3.27 ms430580mMesrline2TxPower r Line 2 SFP Transmitted Power :This
OID gives the transmit power value of
the transceiver Line 2, read from the
DDM (Digital Diagnostic Monitoring)
(Unit = dBm)
1.3.6.1.4.1.20044.21.3.3.28 ms430580mMesrline2RxPower r Line 2 SFP Received Power: This OID
gives the receive power value of the
transceiver Line 2, read from the DDM
(Digital Diagnostic Monitoring) (Unit
= dBm)
1.3.6.1.4.1.20044.21.6 ms430580mcontrolsWrite
1.3.6.1.4.1.20044.21.6.1 ms430580mCtrlOther
1.3.6.1.4.1.20044.21.6.1.0 ms430580mCtrlsynth0
1.3.6.1.4.1.20044.21.6.1.0.1 ms430580mCtrlConfLoad r/w Load Configuration Tables: When set
this enables loading from flash
configuration1 into the module.
1.3.6.1.4.1.20044.21.6.1.0.9 ms430580mCtrlConfFlash r/w Write Configuration Tables: This bit
saves the current configuration of the
module as configuration in the flash.
1.3.6.1.4.1.20044.21.6.1.0.13 ms430580mCtrlConfClear r/w Clear Configuration Tables :This bit
clears the configuration tables from
configuration in the flash.
1.3.6.1.4.1.20044.21.6.1.4 ms430580mCtrlsynth4
1.3.6.1.4.1.20044.21.6.1.4.1 ms430580mCtrlCorrelatOn r/w Enable Alarm Correlation: This OID
enables the alarm correlation in the
MS module.