OverviewMedia Converter/Signal Repeater module is a part of MICROSENS 10G TransportPlatform, a high performance and flexible carrier-class transmissio
Media Converter/Signal Repeater page 10/29NAME DESCRIPTION ACTIONms430580mAlmLine1RxPwrHighWng TRSCV 1 Rx Power Highwarning: Warning indicatingthat th
Media Converter/Signal Repeater page 11/29NAME DESCRIPTION ACTIONms430580mAlmLine1RxPwrHighAla TRSCV 1 Rx Power High: Alarmindicating that the transce
Media Converter/Signal Repeater page 12/29NAME DESCRIPTION ACTIONms430580mAlmLine2TxBiasLowWng TRSCV 2 Bias Low warning:Warning indicating thatthetran
Media Converter/Signal Repeater page 13/29NAME DESCRIPTION ACTIONms430580mAlmLine2TxBiasLowAla TRSCV 2 Bias Low: Alarmindicating that the transceiverl
Media Converter/Signal Repeater page 14/29NAME DESCRIPTION ACTIONms430580mAlmLine2Fail Line 2 Failure: This OIDindicates a failure on the Line 2Corre
Media Converter/Signal Repeater page 15/29MS430580MTrapsNameDescriptionBindings Actionms430580mPortaTrapNotUrgentGoesOnNot urgent Line 1 fault is acti
Media Converter/Signal Repeater page 16/29procedure describes the steps to follow to perform a hardware reset of the MS430580Mmodule.Procedure• Using
Media Converter/Signal Repeater page 17/29− Set to “on “the object: ms430580mCtrlColdResetLocation:…\microsens\modulems430580m\ms430580mcontrolsWrite\
Media Converter/Signal Repeater page 18/29temperature, optical input power, etc. provided by the DDM. The DDM or DigitalDiagnostic Monitoring in each
Media Converter/Signal Repeater page 19/29Location:..\microsens\modulems430580m\ms430580mmeasures\ms430580mMesrLine\Give the 3V3 voltage value of the
Media Converter/Signal Repeater page 2/29IntroductionMedia Converter/Signal Repeater range is a MICROSENS 10G Transport Platformallowing Media convers
Media Converter/Signal Repeater page 20/29Transmit PowerThe object:• ms430580mMesrportaTxPowerLocation:..\microsens\modulems430580m\ms430580mmeasures\
Media Converter/Signal Repeater page 21/29Power in dBm or mW can be obtained by applying the following formula to thereturned value:Rx_Pwr(mW) = AV/10
Media Converter/Signal Repeater page 22/29MS430580M MIB descriptionOID Name Access Description1.3.6.1.4.1.20044.21.2 ms430580malarms1.3.6.1.4.1.20044.
Media Converter/Signal Repeater page 23/29OID Name Access Description1.3.6.1.4.1.20044.21.2.2.3.8.1 ms430580mAlmLine1TrscvAbsent r Line 1 SFP not pl
Media Converter/Signal Repeater page 24/29OID Name Access Description1.3.6.1.4.1.20044.21.2.3.1.28.8 ms430580mAlmLine2TempHighWng r TRSCV 2 Temp Hig
Media Converter/Signal Repeater page 25/29OID Name Access Description1.3.6.1.4.1.20044.21.2.3.2.26.15 ms430580mAlmLine2RxPwrLowAla r TRSCV 2 Rx Powe
Media Converter/Signal Repeater page 26/29OID Name Access Description1.3.6.1.4.1.20044.21.3.2.18 ms430580mMesrline1TxBias r Line 1 SFP Laser bias: T
Media Converter/Signal Repeater page 27/29OID Name Access Description1.3.6.1.4.1.20044.21.6.1.4.2 ms430580mCtrlCorrelatOff r/w Disable Alarm Correla
Media Converter/Signal Repeater page 28/29OID Name Access Description1.3.6.1.4.1.20044.21.9.2.2 ms430580mtablelineStartup1.3.6.1.4.1.20044.21.9.2.2.2
Media Converter/Signal Repeater page 29/29 Front Panel LayoutThe MS430580M occupies one slot in the MICROSENS chassis. Line and Client interfacesare S
Media Converter/Signal Repeater page 3/29• Front panel LEDs indicating the status of the interfaces and the MS430580Mcommon functionsFigure 1: MS43058
Media Converter/Signal Repeater page 4/29Generation Unit can provide a reference clock to supLine 1 bitrate from 125 Mb/s up to2.67 Gb/s. Therefore th
Media Converter/Signal Repeater page 5/29 SNMP User ManualAccess ConfigurationCertain aspects of the Line 1 and Line 2 are user modifiable. In the fol
Media Converter/Signal Repeater page 6/29The following table details the meaning of each bit as well as the default values:ms430580mCfgportbTrscvCtrl
Media Converter/Signal Repeater page 7/29The Line and Client configuration modification can be performed at the same time andapplied at the same time
Media Converter/Signal Repeater page 8/29Location…\microsens\mgnt2\mgnt2SNMPAgentData\mgnt2ModulesManagement\Change if necessary.The following are inv
Media Converter/Signal Repeater page 9/29NAME DESCRIPTION ACTIONms430580mAlmModuleGlobFailure Module Failure: This OID is set ondetection of a failure