Overview
Media Converter/Signal Repeater module is a part of MICROSENS 10G Transport
Platform, a high performance and flexible carrier-class transmission system. The 10G
Transport Platform enables increasing transport capacitities in CWDM, DWDM and SDH
networks. The use of wide range TDM modules permits to reduce the number of
necessary wavelengths and to decrease the overall cost of the application. Ethernet
over SDH modules enable using exisiting SONET/SDH infractructure for IP transmission.
The general features of the system:
19“ 2U Chassis with 5 module slots and management card
Max. 5x single size modules f.ex. 2x double size + 1x single size module
Hot swappable modules & power supplies
Redundant power supplies with -48 VDC input (opt. 230 VAC)
Exchangeable air- and filter module
Wide range of functional xWDM and TDM modules available
The functional modules of 10G Transport Platform include:
TDM 8x GBE or 8x GFC to 10G/OC-192/STM-64
TDM 5x GBE or 5x 2GFC to OC-192/STM-64
TDM 4x OC-48/STM-16 to 10G/OC-192/STM-64
TDM 2x GBE and 2x GFC to OC-48/STM-16
10G transponder with 3R, XFP and fixed Laser Versions
10G protocol converter 10G LAN to 10G WAN (OC-192/STM-64)
DWDM MUX/DeMUX, OADMs, EDFAs
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
MICROSENS
Media Converter/Signal Repeater
Module
Przeglądanie stron 0
1 2 3 4 5 6 ... 28 29

Podsumowanie treści

Strona 1 - MICROSENS

OverviewMedia Converter/Signal Repeater module is a part of MICROSENS 10G TransportPlatform, a high performance and flexible carrier-class transmissio

Strona 2 - System description

Media Converter/Signal Repeater page 10/29NAME DESCRIPTION ACTIONms430580mAlmLine1RxPwrHighWng TRSCV 1 Rx Power Highwarning: Warning indicatingthat th

Strona 3

Media Converter/Signal Repeater page 11/29NAME DESCRIPTION ACTIONms430580mAlmLine1RxPwrHighAla TRSCV 1 Rx Power High: Alarmindicating that the transce

Strona 4 - Interface Specifications

Media Converter/Signal Repeater page 12/29NAME DESCRIPTION ACTIONms430580mAlmLine2TxBiasLowWng TRSCV 2 Bias Low warning:Warning indicating thatthetran

Strona 5 - SNMP User Manual

Media Converter/Signal Repeater page 13/29NAME DESCRIPTION ACTIONms430580mAlmLine2TxBiasLowAla TRSCV 2 Bias Low: Alarmindicating that the transceiverl

Strona 6

Media Converter/Signal Repeater page 14/29NAME DESCRIPTION ACTIONms430580mAlmLine2Fail Line 2 Failure: This OIDindicates a failure on the Line 2Corre

Strona 7 - Management

Media Converter/Signal Repeater page 15/29MS430580MTrapsNameDescriptionBindings Actionms430580mPortaTrapNotUrgentGoesOnNot urgent Line 1 fault is acti

Strona 8

Media Converter/Signal Repeater page 16/29procedure describes the steps to follow to perform a hardware reset of the MS430580Mmodule.Procedure• Using

Strona 9

Media Converter/Signal Repeater page 17/29− Set to “on “the object: ms430580mCtrlColdResetLocation:…\microsens\modulems430580m\ms430580mcontrolsWrite\

Strona 10 - NAME DESCRIPTION ACTION

Media Converter/Signal Repeater page 18/29temperature, optical input power, etc. provided by the DDM. The DDM or DigitalDiagnostic Monitoring in each

Strona 11

Media Converter/Signal Repeater page 19/29Location:..\microsens\modulems430580m\ms430580mmeasures\ms430580mMesrLine\Give the 3V3 voltage value of the

Strona 12

Media Converter/Signal Repeater page 2/29IntroductionMedia Converter/Signal Repeater range is a MICROSENS 10G Transport Platformallowing Media convers

Strona 13

Media Converter/Signal Repeater page 20/29Transmit PowerThe object:• ms430580mMesrportaTxPowerLocation:..\microsens\modulems430580m\ms430580mmeasures\

Strona 14

Media Converter/Signal Repeater page 21/29Power in dBm or mW can be obtained by applying the following formula to thereturned value:Rx_Pwr(mW) = AV/10

Strona 15 - Software Management

Media Converter/Signal Repeater page 22/29MS430580M MIB descriptionOID Name Access Description1.3.6.1.4.1.20044.21.2 ms430580malarms1.3.6.1.4.1.20044.

Strona 16

Media Converter/Signal Repeater page 23/29OID Name Access Description1.3.6.1.4.1.20044.21.2.2.3.8.1 ms430580mAlmLine1TrscvAbsent r Line 1 SFP not pl

Strona 17 - Monitoring

Media Converter/Signal Repeater page 24/29OID Name Access Description1.3.6.1.4.1.20044.21.2.3.1.28.8 ms430580mAlmLine2TempHighWng r TRSCV 2 Temp Hig

Strona 18

Media Converter/Signal Repeater page 25/29OID Name Access Description1.3.6.1.4.1.20044.21.2.3.2.26.15 ms430580mAlmLine2RxPwrLowAla r TRSCV 2 Rx Powe

Strona 19

Media Converter/Signal Repeater page 26/29OID Name Access Description1.3.6.1.4.1.20044.21.3.2.18 ms430580mMesrline1TxBias r Line 1 SFP Laser bias: T

Strona 20

Media Converter/Signal Repeater page 27/29OID Name Access Description1.3.6.1.4.1.20044.21.6.1.4.2 ms430580mCtrlCorrelatOff r/w Disable Alarm Correla

Strona 21 - Appendixes

Media Converter/Signal Repeater page 28/29OID Name Access Description1.3.6.1.4.1.20044.21.9.2.2 ms430580mtablelineStartup1.3.6.1.4.1.20044.21.9.2.2.2

Strona 22 - MS430580M MIB description

Media Converter/Signal Repeater page 29/29 Front Panel LayoutThe MS430580M occupies one slot in the MICROSENS chassis. Line and Client interfacesare S

Strona 23

Media Converter/Signal Repeater page 3/29• Front panel LEDs indicating the status of the interfaces and the MS430580Mcommon functionsFigure 1: MS43058

Strona 24

Media Converter/Signal Repeater page 4/29Generation Unit can provide a reference clock to supLine 1 bitrate from 125 Mb/s up to2.67 Gb/s. Therefore th

Strona 25

Media Converter/Signal Repeater page 5/29 SNMP User ManualAccess ConfigurationCertain aspects of the Line 1 and Line 2 are user modifiable. In the fol

Strona 26

Media Converter/Signal Repeater page 6/29The following table details the meaning of each bit as well as the default values:ms430580mCfgportbTrscvCtrl

Strona 27

Media Converter/Signal Repeater page 7/29The Line and Client configuration modification can be performed at the same time andapplied at the same time

Strona 28

Media Converter/Signal Repeater page 8/29Location…\microsens\mgnt2\mgnt2SNMPAgentData\mgnt2ModulesManagement\Change if necessary.The following are inv

Strona 29 - Order Information

Media Converter/Signal Repeater page 9/29NAME DESCRIPTION ACTIONms430580mAlmModuleGlobFailure Module Failure: This OID is set ondetection of a failure

Komentarze do niniejszej Instrukcji

Brak uwag