Media Converter/Signal Repeater page 19/29
Location:..\microsens\modulems430580m\ms430580mmeasures\
ms430580mMesrLine\
Give the 3V3 voltage value of the SFP plugged into Line 1 and Line 2, read from the
Digital Diagnostic Monitoring (Unit = V). The following formula must be applied to the
returned value in order to obtain the actual voltage:
3V3 (Volts) = AV/10000
Parameter Meaning Format
AV Article Value Unsigned word (16 bits)
For example:
A listing of the ms430580mMesrportaVolt outputs the following:
***** SNMP QUERY STARTED *****
1: ms430580mMesrportaVolt (integer) 33094
***** SNMP QUERY FINISHED *****
The value returned from the SFP in Line 1 is: 33094.
So applying the formula: 3V3 (Volts) = 33094/10000
Gives an actual value of: 3.3094V
Bias
The object:
ms430580mMesrportaTxBias
Location:..\microsens\modulems430580m\ms430580mmeasures\
ms430580mMesrClient\
The object:
ms430580mMesrportbTxBias
Location:..\microsens\modulems430580m\ms430580mmeasures\
ms430580mMesrLine\
Give the bias value of the SFP plugged into Line 1 and Line 2, read from the Digital
Diagnostic Monitoring (Unit = mA). The following formula must be applied to the
returned value in order to obtain the bias:
Bias(mA) = AV/500
Parameter Meaning Format
AV Article Value Unsigned word (16 bits)
For example:
A listing of the ms430580mMesrportaTxBias outputs the following:
***** SNMP QUERY STARTED *****
1: ms430580mMesrportaTxBias (integer) 11046
***** SNMP QUERY FINISHED *****
The value returned from the SFP in Line 1 is: 11046.
So applying the formula: Bias(mA) = 11046/500
Gives an actual value of: 22.092mA