Bridge Module 10/100Base-TX/100Base-FX Page 3/7
MICROSENS GmbH & Co. KG - Küferstr. 16 - D-59067 Hamm - Tel. +49 (0)2381/9452-0 - Fax -100 - www.microsens.com
Optical Parameter
Multimode Versions
min. Distance
*
: 2 km (full duplex)
min. power: -19 dBm
min. sensitivity: -31 dBm
Wavelength 1310 nm
Connector: SC-duplex (MS416161M2)
ST-duplex (MS416160M2)
Single mode Versions
min. Distance
*
: 15 km (full duplex)
min. power: -15 dBm
min. sensitivity: -31 dBm
max. input power
**
: -7 dBm
Wavelength 1310 nm
Connector: SC-duplex (MS416162M2)
ST-duplex (MS416163M2)
min. Distance
*
: 40 km (full duplex)
min. power: -5 dBm
min. sensitivity: -34 dBm
max. input power
**
: 0 dBm
Wavelength 1310 nm
Connector: SC-duplex (MS416164M2)
min. Distance
*
: 80 km (full duplex)
min. power: -5 dBm
min. sensitivity: -34 dBm
max. input power
**
: 0 dBm
Wavelength 1550 nm
Connector: SC-duplex (MS416165M2)
min. Distance
*
: 125 km (full duplex)
min. power: 0 dBm
min. sensitivity: -37 dBm
max. input power
**
: 0 dBm
Wavelength 1550 nm
Connector: SC-duplex (MS416166M2)
*The given distances are recommendations, which are valid for the complete lifetime of the laser. The distances are
depending on the condition of the transmission line and can vary with the quality of the connected fiber cable, the used
connectors and other parameters. Decisive are the optical transmit power and sensitivity. Longer distances are possible
without any problems.
** Furthermore the maximum input power of the receiver has to be considered. The values given in this datasheet are
minimal (guaranteed) values and can be exceeded by 5-7 dB. If he maximum input levels are exceeded for a long time the
device can be damaged.
It is recommended not to mix versions with different distances in one application, e.g. the 15 km version together with the
40 km version. The correct operation can not be guaranteed in this configuration.